Industrial Dry-Type Isolation Transformers

Industrial isolation transformers separate circuits, adapt voltage and support equipment interfaces in machinery, mining systems, drive applications, production lines and other engineered loads. Selection depends on the input and output system, load waveform, duty cycle, environment and protection philosophy. This page focuses on industrial isolation duty and should not be treated as a substitute for an ordinary dry-type distribution transformer page.

Solutions

We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.

Custom Transformer Engineering

Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).

Charging Infrastructure Solutions

Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.

Residential Energy Storage Solutions

Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.

Industrial, Commercial, and Infrastructure Hubs

Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.

Define the voltage ratio and system

State input voltage, output voltage, phase, frequency, neutral requirement, earthing arrangement and rated kVA. Identify whether the transformer supplies one machine, a group of loads, a drive system or a control network. Special ratios and multi-voltage requirements should be shown on a single-line diagram. Final feasibility, dimensions and test scope must be confirmed for the selected design.

Describe the real load

Motor starting, rectifiers, variable-frequency drives, UPS systems and other nonlinear loads can affect current waveform, heating and acoustic performance. Provide load type, harmonic information, starting current, peak demand, duty cycle and expected overloads. If electrostatic shielding or a particular neutral arrangement is required, include it in the RFQ rather than assuming it is standard.

Select construction and thermal limits

The offered winding material, insulation system, cooling method, temperature rise and enclosure should be matched to the duty and installation. Indoor electrical rooms, dusty workshops, high ambient temperatures and restricted ventilation create different design constraints. Provide room ventilation, ambient range, altitude, dust or moisture exposure and any dimensional limits so the technical review covers the actual site.

Plan protection and integration

The transformer must coordinate with upstream and downstream protection, cable sizes, inrush current and equipment insulation levels. Share the proposed breaker or fuse arrangement, fault level where relevant and any requirement for temperature sensors, surge protection, wheels, terminals or cable boxes. Approved drawings should show connection groups, terminals and installation clearances.

Agree performance and acceptance tests

The enquiry should define impedance, efficiency or loss expectations, temperature-rise limits, insulation tests, ratio and polarity checks, noise limits and any witness requirements. Existing test evidence may cover only a specific model, so every claim should be checked against the exact rating and report number. A single report must not be used to represent an entire product family.

Support OEM and project documentation

Industrial OEMs often need drawings, terminal plans, nameplate data, installation instructions and a repeatable configuration for future machines. State the expected annual volume, target equipment, approval process and change-control needs. For one-off projects, provide the site schedule and inspection requirements. This allows the technical and commercial response to reflect the intended supply relationship.

Request an isolation-transformer review

Send input and output voltage, phase, frequency, kVA, load type, harmonics, duty cycle, insulation and enclosure needs, ambient conditions, dimensions, protection concept, required tests, quantity and destination. LONTEN can then determine what additional information is needed and whether a documented configuration can be proposed.

Related Resources

Frequently Asked Questions

An isolation transformer is selected primarily for circuit separation, equipment interface or special voltage conversion. A distribution transformer is selected to deliver power within a distribution network. The load and system purpose should determine the category.

Provide input/output voltage, kVA, frequency, vector group or connection, neutral/earthing, load type, harmonics, duty cycle, environment, enclosure and tests.

Possibly, but the waveform, harmonics, current, duty and thermal requirements must be reviewed. Do not select only by kVA without load data.

Submit the required ratio and system diagram for engineering review. Availability, dimensions and testing must be confirmed for the proposed model.

Report coverage is model-specific. Ask for the report number, rating, standard edition and test items for the exact transformer being quoted.

Project Support

Need help selecting a transformer, EV charging system, or residential energy storage solution?

Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.