SG-20kVA 380V-380V
View Details →
Industrial isolation transformers separate circuits, adapt voltage and support equipment interfaces in machinery, mining systems, drive applications, production lines and other engineered loads. Selection depends on the input and output system, load waveform, duty cycle, environment and protection philosophy. This page focuses on industrial isolation duty and should not be treated as a substitute for an ordinary dry-type distribution transformer page.
We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.
Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).
Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.
Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.
Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.
State input voltage, output voltage, phase, frequency, neutral requirement, earthing arrangement and rated kVA. Identify whether the transformer supplies one machine, a group of loads, a drive system or a control network. Special ratios and multi-voltage requirements should be shown on a single-line diagram. Final feasibility, dimensions and test scope must be confirmed for the selected design.
Motor starting, rectifiers, variable-frequency drives, UPS systems and other nonlinear loads can affect current waveform, heating and acoustic performance. Provide load type, harmonic information, starting current, peak demand, duty cycle and expected overloads. If electrostatic shielding or a particular neutral arrangement is required, include it in the RFQ rather than assuming it is standard.
The offered winding material, insulation system, cooling method, temperature rise and enclosure should be matched to the duty and installation. Indoor electrical rooms, dusty workshops, high ambient temperatures and restricted ventilation create different design constraints. Provide room ventilation, ambient range, altitude, dust or moisture exposure and any dimensional limits so the technical review covers the actual site.
The transformer must coordinate with upstream and downstream protection, cable sizes, inrush current and equipment insulation levels. Share the proposed breaker or fuse arrangement, fault level where relevant and any requirement for temperature sensors, surge protection, wheels, terminals or cable boxes. Approved drawings should show connection groups, terminals and installation clearances.
The enquiry should define impedance, efficiency or loss expectations, temperature-rise limits, insulation tests, ratio and polarity checks, noise limits and any witness requirements. Existing test evidence may cover only a specific model, so every claim should be checked against the exact rating and report number. A single report must not be used to represent an entire product family.
Industrial OEMs often need drawings, terminal plans, nameplate data, installation instructions and a repeatable configuration for future machines. State the expected annual volume, target equipment, approval process and change-control needs. For one-off projects, provide the site schedule and inspection requirements. This allows the technical and commercial response to reflect the intended supply relationship.
Send input and output voltage, phase, frequency, kVA, load type, harmonics, duty cycle, insulation and enclosure needs, ambient conditions, dimensions, protection concept, required tests, quantity and destination. LONTEN can then determine what additional information is needed and whether a documented configuration can be proposed.
Project Support
Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.