40 kW Floor-Standing Compact DC Charger

40 kW floor-standing compact DC charger

Product Profile

Short Description: A dedicated 40kW Compact DC Charger SKU with a DC 50-1000 V adjustable output range, IP54 protection and network communication.

Product Description: This compact DC charger is designed for space-conscious commercial, public and fleet charging deployments. The series supports automatic charging modes, a 7-inch touch display, Ethernet/4G communication and OCPP 1.6 integration.

Key Features:
- Dedicated 40kW SKU
- Floor-standing compact design
- Adjustable DC 50-1000 V output
- 7-inch touch display
- Ethernet/4G communication
- OCPP 1.6 support
- IP54 protection for indoor or outdoor use

Product Applications

Commercial parking facilities Public EV charging sites Fleet depots Workplace charging Indoor or outdoor charging locations with compatible electrical supply
Request a Quote Reply within 1 business day

Technical Specifications

Power & Output

Parameter Value Unit Notes
Rated Power 40 kW Dedicated SKU
Maximum Output Current 133 A Single gun
Input Voltage AC 380 V ±20% — —
Input Frequency 50 Hz ±10% — As stated in PDF
Output Voltage Range DC 50-1000 V Adjustable
Constant-Power Output Voltage Range DC 300-1000 V Optional
Output Voltage Error ≤±0.5 % —
Output Current Error ≤±1 % —
Voltage Regulation Accuracy ≤±0.5 % —
Steady Current Accuracy ≤±1 % —
Harmonic Content ≤±5 % —
Power Factor ≄0.99 — —
Efficiency ≄95 % —
Electric Energy Metering Grade 1.0 meets GB standard — —
Insulation Resistance ≄100 MĪ© —

Charging & Communication

Parameter Value Unit Notes
Number of Charging Guns Single gun — —
Charging Cable Length 5 m Standard; listed as optional
Display 7-inch touch display — —
Start Method Swipe IC card / scan QR code (APP, WeChat, etc.) — —
Charging Mode Automatic / by time / by power / by amount — —
Charging Method Full power charging / AB equalizing charging / wheel charging — As stated in PDF
Communication Ethernet / 4G optional — —
Network Protocol OCPP 1.6 — Catalog series statement

Protection, Environment & Mechanical

Parameter Value Unit Notes
Protection Functions Short circuit / overtemperature / overcurrent / leakage / input overvoltage and undervoltage — —
Protection Class IP54 — —
Use Environment Indoor or outdoor — —
Cooling Method Air cooling — —
Operating Temperature -20 to +50 °C —
Storage Temperature -40 to +70 °C —
Relative Humidity 5-95 % —
Altitude ≤2000 m —
Noise ≤60 dB —
Installation Method Floor installation — —
Dimensions (WƗHƗD) 1620Ɨ570Ɨ282 mm —

Application Scenarios

Industrial Facilities

Power distribution for manufacturing plants, factories, and industrial complexes.

Commercial Buildings

Office buildings, shopping centers, and commercial complexes.

Infrastructure

Public utilities, transportation, and municipal power systems.

Renewable Energy

Solar farms, wind power installations, and energy storage systems.

Solutions

We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.

Custom Transformer Engineering

Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).

Charging Infrastructure Solutions

Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.

Residential Energy Storage Solutions

Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.

Industrial, Commercial, and Infrastructure Hubs

Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.

Check 40 kW against the operating plan

Build a demand model from arrival peaks, battery voltage, target dwell time, session energy and future utilization. Confirm vehicle acceptance and site capacity rather than treating rated charger power as a guaranteed charging time.

Review the listed 133 A single-gun output

The record lists DC 50-1000 V and up to 133 A for one gun. DC 300-1000 V constant-power operation is marked optional. Request the selected module configuration, current-power curve, cable, connector and derating limits.

Design the compact floor installation

Floor installation and dimensions of 1620 Ɨ 570 Ɨ 282 mm are listed. Coordinate foundation, anchoring, clearances, drainage, ventilation, cable entry, impact protection, lifting, service access and the final GA drawing.

Integrate the charger with the grid

The listed input is AC 380 V ±20% at 50 Hz ±10%, with power factor at least 0.99 and efficiency at least 95%. Verify upstream switchgear, protection, earthing, fault level, harmonics, transformer loading and acceptance tests for the site.

Confirm communication and environmental scope

The record lists Ethernet, optional 4G, a 7-inch display, OCPP 1.6 as a series statement, IP54, air cooling and indoor or outdoor use. Confirm firmware, backend, connector and environmental test evidence; do not call protocol support certified without proof.

Related planning resources

Frequently Asked Questions

The production record lists a maximum 133 A for its single-gun configuration. Confirm the current-power curve, cable rating and vehicle-voltage operating point.

The DC 300-1000 V constant-power range is marked optional in the record. Confirm whether it is included in the quoted module configuration and supporting datasheet.

Confirm the GA drawing, foundation, anchors, clearances, drainage, cable entry, ventilation, impact protection and service access for the selected site.

No connector is established by the current evidence. Specify the vehicle fleet and country and verify the connector, cable and applicable documents for the exact configuration.

Treat it as a listed model value to be reconfirmed with test conditions and acceptance criteria. Do not extend it to other chargers, voltages or ambient conditions.

Project Support

Need help selecting a transformer, EV charging system, or residential energy storage solution?

Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.