60 kW Compact Single-Gun DC Charger

60 kW compact single-gun DC charger

Product Profile

Short Description: A dedicated 60kW Compact DC Charger SKU with a DC 50-1000 V adjustable output range, IP54 protection and network communication.

Product Description: This compact DC charger is designed for space-conscious commercial, public and fleet charging deployments. The series supports automatic charging modes, a 7-inch touch display, Ethernet/4G communication and OCPP 1.6 integration.

Key Features:
- Dedicated 60kW SKU
- Floor-standing compact design
- Adjustable DC 50-1000 V output
- 7-inch touch display
- Ethernet/4G communication
- OCPP 1.6 support
- IP54 protection for indoor or outdoor use

Product Applications

Commercial parking facilities Public EV charging sites Fleet depots Workplace charging Indoor or outdoor charging locations with compatible electrical supply
Request a Quote Reply within 1 business day

Technical Specifications

Power & Output

Parameter Value Unit Notes
Rated Power 60 kW Dedicated SKU
Maximum Output Current 200 A Single gun
Input Voltage AC 380 V ±20% — —
Input Frequency 50 Hz ±10% — As stated in PDF
Output Voltage Range DC 50-1000 V Adjustable
Constant-Power Output Voltage Range DC 300-1000 V Optional
Output Voltage Error ≤±0.5 % —
Output Current Error ≤±1 % —
Voltage Regulation Accuracy ≤±0.5 % —
Steady Current Accuracy ≤±1 % —
Harmonic Content ≤±5 % —
Power Factor ≄0.99 — —
Efficiency ≄95 % —
Electric Energy Metering Grade 1.0 meets GB standard — —
Insulation Resistance ≄100 MĪ© —

Charging & Communication

Parameter Value Unit Notes
Number of Charging Guns Single gun — —
Charging Cable Length 5 m Standard; listed as optional
Display 7-inch touch display — —
Start Method Swipe IC card / scan QR code (APP, WeChat, etc.) — —
Charging Mode Automatic / by time / by power / by amount — —
Charging Method Full power charging / AB equalizing charging / wheel charging — As stated in PDF
Communication Ethernet / 4G optional — —
Network Protocol OCPP 1.6 — Catalog series statement

Protection, Environment & Mechanical

Parameter Value Unit Notes
Protection Functions Short circuit / overtemperature / overcurrent / leakage / input overvoltage and undervoltage — —
Protection Class IP54 — —
Use Environment Indoor or outdoor — —
Cooling Method Air cooling — —
Operating Temperature -20 to +50 °C —
Storage Temperature -40 to +70 °C —
Relative Humidity 5-95 % —
Altitude ≤2000 m —
Noise ≤60 dB —
Installation Method Floor installation — —
Dimensions (WƗHƗD) 1620Ɨ570Ɨ282 mm —

Application Scenarios

Industrial Facilities

Power distribution for manufacturing plants, factories, and industrial complexes.

Commercial Buildings

Office buildings, shopping centers, and commercial complexes.

Infrastructure

Public utilities, transportation, and municipal power systems.

Renewable Energy

Solar farms, wind power installations, and energy storage systems.

Solutions

We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.

Custom Transformer Engineering

Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).

Charging Infrastructure Solutions

Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.

Residential Energy Storage Solutions

Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.

Industrial, Commercial, and Infrastructure Hubs

Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.

Size the site for a compact 60 kW charger

Model vehicle arrivals, battery voltage, target dwell time, session energy, utilization and expansion. Review the utility connection, transformer, switchgear and demand control needed for the 60 kW compact single-gun duty.

Use the listed 200 A value correctly

The production record lists one gun, DC 50-1000 V output and a maximum 200 A. Confirm current at the required voltage, the optional DC 300-1000 V constant-power range, cable thermal limit, connector and any derating.

Keep the compact and dual-gun pages separate

This page covers the compact single-gun record. The separate 60 kW floor-standing product lists single- and dual-gun configurations and unresolved 125/200 A mapping. Do not combine their gun count, dimensions, current or OCPP evidence.

Coordinate floor layout and power quality

The compact record lists floor installation and 1620 Ɨ 570 Ɨ 282 mm dimensions. Confirm foundation, cable entry, ventilation, service space and impact protection, together with upstream protection, earthing, fault level, harmonics and transformer loading.

Verify communications and listed performance

Ethernet, optional 4G, a 7-inch display, OCPP 1.6 at series level, IP54, power factor at least 0.99 and efficiency at least 95% appear in the record. Reconfirm firmware, CSMS, test conditions and model scope; do not infer connector or certification.

Related 60 kW resources

Frequently Asked Questions

Yes. Its production record lists one charging gun and a maximum 200 A. Confirm the connector, cable and current available across the vehicle voltage range.

Product 61 is the compact single-gun record with its own dimensions and 200 A value. Product 62 is a separate floor-standing record with single- and dual-gun configurations and pending current mapping.

The series data lists OCPP 1.6, but certification is not established. Confirm firmware, feature profile, CSMS testing and any required interoperability evidence.

Do not assume that it does. Request the current-power curve, module limits, constant-power range, cable rating and derating for the quoted model.

Provide available capacity, voltage, fault level, transformer and switchgear data, protection, earthing, harmonics, demand limits and future expansion.

Project Support

Need help selecting a transformer, EV charging system, or residential energy storage solution?

Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.