360 kW High-Power Dual-Gun DC Charger

360 kW high-power dual-gun DC charger

Product Profile

Short Description: A dedicated 360kW Ultra-Fast DC Charger SKU with dual charging guns, an adjustable DC 50-1000 V output range and OCPP 1.6 connectivity.

Product Description: Designed for high-throughput charging sites, this floor-standing charger combines high-power DC output with intelligent power distribution, network communication and thermal management for continuous operation.

Key Features:
- Dedicated 360kW SKU
- Dual charging guns
- Adjustable DC 50-1000 V output
- OCPP 1.6 support
- Ethernet/4G communication
- 7-inch touch display
- IP54 protection for indoor or outdoor use
- Automatic charging modes and multiple protection functions

Product Applications

High-throughput public charging stations Highway fast-charging sites Fleet depots Bus charging facilities Compatible heavy-duty and commercial EV charging projects
Request a Quote Reply within 1 business day

Technical Specifications

Power & Output

Parameter Value Unit Notes
Rated Power 360 kW Dedicated SKU
Number of Charging Guns Double guns — —
Single-Gun Maximum Output Current 300 A —
Input Voltage AC 380 V ±20% — —
Input Frequency 50 Hz ±10% — As stated in PDF
Output Voltage Range DC 50-1000 V Adjustable
Constant-Power Output Voltage Range DC 300-1000 V Optional
Output Voltage Error ≤±0.5 % —
Output Current Error ≤±1 % —
Voltage Regulation Accuracy ≤±0.5 % —
Steady Current Accuracy ≤±1 % —
Harmonic Content ≤±5 % —
Power Factor ≄0.99 — —
Efficiency ≄95 % —
Electric Energy Metering Grade 1.0 meets GB standard — —
Insulation Resistance ≄100 MĪ© —

Charging & Communication

Parameter Value Unit Notes
Charging Cable Length 5 m Standard; listed as optional
Display 7-inch touch display — —
Start Method Swipe IC card / scan QR code (APP, WeChat, etc.) — —
Charging Mode Automatic / by time / by power / by amount — —
Charging Method Full power charging / AB equalizing charging / wheel charging — As stated in PDF
Communication Ethernet / 4G — —
Network Protocol OCPP 1.6 — —

Protection, Environment & Mechanical

Parameter Value Unit Notes
Protection Functions Short circuit / overtemperature / overcurrent / leakage / input overvoltage and undervoltage — —
Protection Class IP54 — —
Use Environment Indoor or outdoor — —
Cooling Method Air cooling — —
Operating Temperature -20 to +50 °C —
Storage Temperature -40 to +70 °C —
Relative Humidity 5-95 % —
Altitude ≤2000 m —
Noise ≤60 dB —
Installation Method Floor installation — —
Dimensions (WƗDƗH) 800Ɨ650Ɨ1900 mm —

Application Scenarios

Industrial Facilities

Power distribution for manufacturing plants, factories, and industrial complexes.

Commercial Buildings

Office buildings, shopping centers, and commercial complexes.

Infrastructure

Public utilities, transportation, and municipal power systems.

Renewable Energy

Solar farms, wind power installations, and energy storage systems.

Solutions

We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.

Custom Transformer Engineering

Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).

Charging Infrastructure Solutions

Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.

Residential Energy Storage Solutions

Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.

Industrial, Commercial, and Infrastructure Hubs

Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.

Start with a high-power site study

Model vehicle arrivals, battery voltage, session energy, dwell time, simultaneous use and expansion. Coordinate utility service, transformer, switchgear, protection and demand management before selecting 360 kW capacity.

Review output at the vehicle voltage

The record lists two guns, DC 50-1000 V and a 300 A single-gun maximum. Confirm per-gun current-power curves, total allocation, simultaneous rules, connector and cable. The DC 300-1000 V constant-power range is optional.

Validate power distribution and thermal duty

The description refers to intelligent power distribution and thermal management, but control logic and continuous-duty performance need model evidence. Request module allocation, derating, heat-rejection, fan strategy, alarms and acceptance tests.

Plan the floor installation

The record lists 800 Ɨ 650 Ɨ 1900 mm dimensions, IP54, air cooling and floor installation. Confirm foundation, drainage, cable routing, bollards, clearances, ventilation, noise, lifting and maintenance access for the actual site.

Confirm protocol and operating scope

OCPP 1.6, Ethernet/4G and a 7-inch display are listed. Verify firmware, CSMS profile, authorization, metering, cybersecurity and remote service. Do not infer certified interoperability, payment, connector compliance or a fixed charging time.

Related high-power chargers

Frequently Asked Questions

High-power is used as a neutral equipment descriptor. Actual charging speed depends on the vehicle, battery, voltage, current, temperature and site conditions, not the product name alone.

The record lists a 300 A single-gun maximum. Confirm per-gun curves, total power allocation, simultaneous limits, cable and connector for the quoted configuration.

The DC 300-1000 V constant-power range is marked optional. Confirm the selected module configuration and supporting datasheet.

No. Confirm firmware, supported feature profile, CSMS testing and any certification or interoperability evidence required by the project.

Provide the load model, grid and transformer data, connector, gun allocation, power-quality study, civil layout, networking, environment and required reports.

Project Support

Need help selecting a transformer, EV charging system, or residential energy storage solution?

Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.