SCB13 35 kVA 15 kV to 0.4 kV Dry-Type Transformer

SCB13 35 kVA 15 kV to 0.4 kV dry-type transformer

Product Profile

SC(B) Dry-type transformer series with high efficiency and reliable performance

Product Applications

Industrial Power Distribution Commercial Buildings Infrastructure Projects Renewable Energy
Request a Quote Reply within 1 business day

Technical Specifications

Parameter Value Unit Notes
power 35 kVA — —
voltage 15kV-0.4kV — —
material Cast Resin — Database listing; confirm the material and construction in the quoted model datasheet and drawings.
standard IEC/IEEE — Database reference only; confirm the required standard, edition and model-specific compliance evidence.

Application Scenarios

Industrial Facilities

Power distribution for manufacturing plants, factories, and industrial complexes.

Commercial Buildings

Office buildings, shopping centers, and commercial complexes.

Infrastructure

Public utilities, transportation, and municipal power systems.

Renewable Energy

Solar farms, wind power installations, and energy storage systems.

Solutions

We are more than just an equipment manufacturer; we are dedicated to providing specialized end-to-end solutions for EPC contractors, industrial developers, and public infrastructure projects.

Custom Transformer Engineering

Delivering bespoke designs tailored to specific voltage requirements, extreme climate resilience (for African grids), and high-efficiency industrial upgrades (for the North American market).

Charging Infrastructure Solutions

Providing comprehensive turnkey solutions for charging station construction, deeply integrating highly reliable transformers with intelligent power distribution systems to empower the future of mobility.

Residential Energy Storage Solutions

Combining LiFePO4 batteries, single-phase solar inverters, and integrated backup systems for household solar self-consumption and resilient home power.

Industrial, Commercial, and Infrastructure Hubs

Providing robust power distribution architectures for manufacturing plants, mining operations, and modern urban infrastructure.

Confirm the listed 15 kV to 0.4 kV rating

The production record lists a 0.4 kV low-voltage side. Confirm system nominal voltage, highest voltage for equipment, frequency, phase, insulation level, vector group, neutral and taps so the final quotation, schedule and nameplate use the verified electrical interface.

Match 35 kVA to the connected load

Provide continuous demand, starting current, power factor, harmonic content, duty cycle and growth allowance. Small auxiliary or local distribution loads can have high starting or nonlinear components, so capacity should be reviewed from the load list.

Clarify the SCB13 model definition

The production record lists SCB13 and the material field lists Cast Resin, but it does not prove a construction difference from the SC13 35 kVA listing. Ask for the model matrix, winding and casting details, insulation data, terminals and enclosure for the offered unit.

Integrate switching, earthing and protection

Share the upstream switching or fuse arrangement, downstream protective devices, earthing system and fault level. Request impedance and inrush data if needed for selectivity and protection settings.

Check dimensions and environmental limits

Declare ambient temperature, altitude, humidity, dust, ventilation and clearance constraints. Confirm dimensions, weight, terminal position, cable approach, enclosure and any accessories before approving the installation.

Limit standards to documented scope

The IEC/IEEE field in the database is not a blanket compliance statement. Specify the required standard and edition, then confirm that drawings, reports and declarations cover the SCB13 35 kVA, 15 kV to 0.4 kV model offered.

Related model and RFQ pages

Frequently Asked Questions

The production record lists 15 kV to 0.4 kV. The final quotation, technical schedule and nameplate rating must be confirmed against the selected model documents.

It confirms the listed model identity. It does not by itself establish winding construction, losses, enclosure or a technical difference from SC13; those points require model documents.

Review the connected load, demand, starting current, power factor, harmonics, duty cycle and future allowance. Confirm the selection in the project technical schedule.

No. It is a database reference field. Compliance should only be stated after the required standard, edition, quoted model and supporting reports have been matched.

Provide ambient temperature, altitude, ventilation, dust or humidity exposure, clearances, cable entry, switching, protection and earthing requirements, plus the required enclosure.

Project Support

Need help selecting a transformer, EV charging system, or residential energy storage solution?

Our engineering team can match the right configuration to your operating environment, charging demand, safety requirements, and household energy goals.